Kleenpak capsules are manufactured using gamma-irradiation tolerant materials and offer the very highest standard of filtration security and user convenience.These filters can be integrated within gamma-irradiatable or gamma-sterilized complex systems such as biorectors, filter assemblies, or transfer sets where venting is required.
Pre-sterilized Option
Kleenpak filters can be supplied sterilized by a validated gamma-irradiation process reducing time and costs.Filter capsules are then double-bagged and the outlet is covered with a protective cap for extra security.
Gamma-irradiatable Option
The capsules can also be supplied non-sterile, allowing the connection to tubing or any other type of equipment prior to gamma irradiation.This allows users to have a sterilized processing system without the need for aseptic connections and the associated risks of contamination.
Custom-made Sets
We are happy to work with end-users to provide custom-designed processing systems which will integrate one or more of our capsule ranges.
特色及优点
- Highly retentive Emflon II membrane
- High flow-rates associated with low Delta P enable the use of small filters — reduction of installation and operating costs
- Gamma-irradiatable or pre-sterilized for maximum convenience
- Integral molded connections
- Fully integrity testable using the forward flow test
High Quality Standards
-
Validated in liquids with Brevundimonas diminuta (ATCC 19146) at a challenge level of
107 organisms/cm2 of filter area - 100 % integrity tested during manufacturing
- Identified by a lot number with a unique serial number for complete traceability of manufacturing history and for user traceability systems
- Each filter supplied with a Certificate of Test
- Comprehensive validation guide available
- Manufactured under a Quality Management System certified to ISO 9000
-
Meets USP Biological Reactivity Tests in vivo, in accordance with USP Class VI plastics
at 121 °C
材料成分
膜 | Hydrophobic PVDF |
Support and Drainage Layers | 聚丙烯 |
End Cap, Core and Cage | 聚丙烯 |
Outer Shell | 聚丙烯 |
Vent and Drain Valve O-rings | Ethylene Propylene (EPDM) |
Nominal Dimensions
KA02 | KA1 | KA2 | KA3 | |
Maximum Diameter (Including Valves) |
51 mm |
94 mm |
94 mm (3.7 in.) |
109 mm (4.2 in.) |
Length with Hose Barb Connections (Code 2) |
104 mm (4.1 in.) |
钠 | 钠 | 钠 |
Length with Sanitary Connections | 钠 |
11.7 cm (4.6 in.) |
15.8 cm (6.2 in.) |
17.4 cm (6.8 in.) |
Nominal Filtration Area |
200 cm2 (0.21 ft2) |
500 cm2 (0.5 ft2) |
1000 cm2 (1.0 ft2) |
1500 cm2 (1.5 ft2) |
Operating Conditions1
KA02 | |
Maximum operating pressure | 4.1 barg (60 psig) at 38 °C |
Maximum Differential Pressure | 2.1 bard (30 psid) at 80 °C |
KA1/KA2/KA3 | |
Maximum Operating Temperature | 40 °C |
Maximum operating pressure | 3.5 barg (50 psig) at 40 °C |
Typical Air Flow Rates2
2 For gases other than air or nitrogen, contact 上海羽令.
Sterilization
Gamma-irradiation Maximum Dosage (G option only) | Up to 50 kGy |
Autoclave Sterilization: |
|
Warning:Kleenpak filters must not be in situ steam-sterilized by passing steam through under pressure.The figures are maximum allowable figures determined by testing under controlled laboratory conditions to the total number of hours indicated.Actual operating conditions may affect the filters long-term response to sterilization.Filters should be qualified for each process application.
描述 | Part Number |
KA1V002PV1S | Kleenpak™ capsule with Emflon® II membrane, max diameter 3.7 in, with 1½ in. sanitary flange, gamma-irradiated |
KA1V002PV1G | Kleenpak capsule with Emflon II membrane, max diameter 3.7 in, with 1½ in. sanitary flange, non-irradiated |
KA1V002PV2S | Kleenpak capsule with Emflon II membrane, max diameter 3.7 in, with ¼ -½ in hose barb, gamma-irradiated |
KA1V002PV2G | Kleenpak capsule with Emflon II membrane, max diameter 3.7 in, with ¼ -½ in hose barb, non-irradiated |
KA2V002PV1S | Kleenpak capsule with Emflon II membrane, max diameter 3.7 in, with 1½ in. sanitary flange, gamma-irradiated |
KA2V002PV1G | Kleenpak capsule with Emflon II membrane, max diameter 3.7 in, with 1½ in. sanitary flange, non-irradiated |
KA2V002PV2S | Kleenpak capsule with Emflon II membrane, max diameter 3.7 in, with ¼ -½ in hose barb, gamma-irradiated |
KA2V002PV2G | Kleenpak capsule with Emflon II membrane, max diameter 3.7 in, with ¼ -½ in hose barb, non-irradiated |
KA3V002PV1S | Kleenpak capsule with Emflon II membrane, max diameter 4.2 in, with 1½ in. sanitary flange, gamma-irradiated |
KA3V002PV1G | Kleenpak capsule with Emflon II membrane, max diameter 4.2 in, with 1½ in. sanitary flange, non-irradiated |
KA3V002PV2S | Kleenpak capsule with Emflon II membrane, max diameter 4.2 in, with ¼ -½ in hose barb, gamma-irradiated |
KA3V002PV2G | Kleenpak capsule with Emflon II membrane, max diameter 4.2 in, with ¼ -½ in hose barb, non-irradiated |