These validated 0.2 micron-rated sterilizing-grade filters retain
Brevundimonas diminuta (ATCC 19146) at 10
7 CFU/cm² effective filter area (EFA) and ensure very low extractables and adsorption.They are recommended for sterilizing filtration of pharmaceutical fluids including solutions with active ingredients, biologicals, biotech proteins, ophthalmics and other dilute preservative solutions.
Novasip™ capsules are the first and only single-use filter capsules that can be sterilized by in-line steaming (SIP).这款功能强大的
囊式过滤器维护成本较低,是不锈钢滤壳和
滤芯组件的理想替代产品,且在过滤器必须整合至 SIP 系统的情况下常被视为唯一的选择。Novasip capsules are certified for use in pharmaceutical manufacturing environments and sized for liquid volumes of 30 L to 500 L or in low-to-moderate flow air/gas/vent applications.
特色及优点
-
Low installation cost - up to 80% less than a comparable stainless steel system
-
Steam-in-place capability with no housing cleaning or maintenance
-
Clear housing for easy venting
-
Laser-etched serial number for easy identification
-
New design sanitary valves
-
Non-removable for safety
-
Non-threaded for cleanliness
-
Integral Stäubli*-compatible vent valve enables direct on-line connection to integrity test equipment
-
Non-rotating hose barb drain for safe and hygienic operation
-
Available in a range of media and removal ratings
* Stäubli is a trademark of Stäubli AG
材料成分
|
Filter Membrane |
Hydrophilic modified PVDF |
Support/Drainage |
聚丙烯 |
End Cap, Core and Cage |
聚丙烯 |
Capsule Bowl |
Polyetherimide |
Sealing Technology |
Thermal bonding without adhesives |
Housing Head |
Polyetherimide with TiO2 whitener¹ |
|
¹ TiO2 is an insoluble inorganic mineral filler that does not contribute to organic extractables
Operating Parameters²
|
Maximum Operating Temperature |
60 °C |
最大操作压力 |
6.5 bar (94 psi) at 40 °C
2.0 bar (29 psi) at 60 °C |
Maximum Differential Pressure (Forward Direction) |
5.3 bar (77 psi) at 40 °C
4.1 bar (60 psi) at 60 °C |
|
² In compatible fluids which do not soften, swell or adversely affect the filter or its materials of construction
Sterilization³
|
Autoclave or In-Situ steam |
3 x 60 minutes at 125 °C
10 x 60 minutes at 140 °C |
|
Typical Extractables in Water at 20 °C³
³ Tested on capsules without pre-flushing
Nominal Dimensions
|
Diameter Incl.Valves |
123 mm (4.8 in.) |
123 mm (4.8 in.) |
Overall Length |
84 mm (3.3 in.) |
157 mm (6.2 in.) |
|
Nominal Effective Filter Area (EFA)
|
CL(M)05 |
400 cm² (0.4 ft²) |
C(L)1 |
700 cm² (0.7 ft²) |
C(L)3 |
1500 cm² (1.6 ft²) |
|