pall,颇尔,Emflon II Membrane in Mini Kleenpak Capsules,KA02V002P2S, KA02V002P2G, KA02V002P8S, KA02V002P8G

产品名称:
Emflon II Membrane in Mini Kleenpak Capsules
产品型号:
KA02V002P2S, KA02V002P2G, KA02V002P8S, KA02V002P8G
产品描述:

产品介绍

pall,颇尔,Emflon II Membrane in Mini Kleenpak Capsules,KA02V002P2S, KA02V002P2G, KA02V002P8S, KA02V002P8G
pall,颇尔,Emflon II Membrane in Mini Kleenpak Capsules

Emflon® II Membrane in Mini Kleenpak™ Capsules
Emflon® II filter assemblies contain hydrophobic polyvinylidenedifluoride (PVDF) membrane, which is designed for use as sterilizing filter for air, gas, and vent service in biopharmaceutical applications.

Mini Kleenpak™ capsules are used in the laboratory for process development and in pilot and manufacturing scale operations if processing requirements do not demand a large filter (process volumes from 2 L to 50 L).They are the smallest capsule filters with a pleated membrane in 颇尔’s UpScalerange and are excellent for modeling filter performance at large production scale.

 

特色及优点

  • Highly-retentive Emflon II membrane for sterility assurance
  • High flow-rates associated with low Delta P enables the use of small filters, leading to reduction of installation and operating costs
  • Gamma-irradiatable or autoclavable for sterilization
  • Available gamma-irradiated
  • Integrity testable using the Forward Flow test
  • Choice of connection options for enhanced flexibility
  • Ease of venting with newly designed valve
 
 

材料成分

 
   Hydrophobic PVDF
 Support and Drainage Layers  聚丙烯
 End Cap, Core and Cage  聚丙烯
 Outer Shell  聚丙烯
 Vent and Drain Valve O-rings  Ethylene Propylene (EPDM)
 

 

Nominal Dimensions

 
 Maximum Diameter (Including Valves)

51 mm (2.0 in.)

 Length with Hose Barb Connections (Code 2) 104 mm  (4.1 in.)
 Length with Sanitary Connections 不可用
 Nominal Filtration Area  200 cm2 (0.21 ft2)      
 

 

Operating Conditions¹

 
Maximum operating pressure        4.1 barg (60 psig) at 38 °C
 Maximum Differential Pressure      2.1 bard (30 psid) at 80 °C
 
1 In air/nitrogen gas service or other compatible fluids, which do not soften, swell, or adversely affect the filter or its materials of construction.

 

Sterilization

 
Gamma-irradiation Maximum Dosage (G option only) Up to 50 kGy

Autoclave Sterilization:    
Gamma-irradiated Filters 

Non Gamma-irradiated Filters


One 30-minute cycle at 125 °C
100 hours at 125 deg °C; 50 hours at 140 deg °C

 
Warning:Kleenpak filters must not be in situ steam-sterilized by passing steam through under pressure.The figures are maximum allowable figures determined by testing under controlled laboratory conditions to the total number of hours indicated.Actual operating conditions may affect the filters long-term response to sterilization.Filters should be qualified for each process application.
 
Part Number 描述
KA02V002P2S Mini Kleenpak™ capsule with Emflon® II membrane, max diameter 2.0 in, with ¼ to ½ in hose barb, gamma-irradiated
KA02V002P2G Mini Kleenpak™ capsule with Emflon® II membrane, max diameter 2.0 in, with ¼ to ½ in hose barb, non-irradiated
KA02V002P8S Mini Kleenpak™ capsule with Emflon® II membrane, max diameter 2.0 in, with ½ in sanitary flange, gamma-irradiated
KA02V002P8G Mini Kleenpak™ capsule with Emflon® II membrane, max diameter 2.0 in, with ½ in sanitary flange, non-irradiated
 

 


pall,颇尔,Emflon II Membrane in Mini Kleenpak Capsules