These 0.1 micron-rated filters with serial layer (0.2/0.1 micron) membrane construction assure high flow rates compared with other 0.1 micron (and even some 0.2 micron)-rated filters.Fluorodyne II grade DJL filters are validated for removal of
Acholeplasma laidlawii mycoplasma (ATCC 28206) with a typical T
R >10
11 and retention of
Brevundimonas diminuta (ATCC 19146) at 10
7 CFU/cm² effective filter area (EFA).This allows enhanced sterilization assurance as well as efficient mycoplasma control.
Novasip™ capsules are the first and only single-use filter capsules that can be sterilized by in-line steaming (SIP).这款功能强大的
囊式过滤器维护成本较低,是不锈钢滤壳和
滤芯组件的理想替代产品,且在过滤器必须整合至 SIP 系统的情况下常被视为唯一的选择。Novasip capsules are certified for use in pharmaceutical manufacturing environments and sized for liquid volumes of 30 L to 500 L or in low-to-moderate flow air/gas/vent applications.
特色及优点
-
Low installation cost - up to 80% less than a comparable stainless steel system
-
Steam-in-place capability with no housing cleaning or maintenance
-
Clear housing for easy venting
-
Laser-etched serial number for easy identification
-
New design sanitary valves
-
Non-removable for safety
-
Non-threaded for cleanliness
-
Integral Stäubli*-compatible vent valve enables direct on-line connection to integrity test equipment
-
Non-rotating hose barb drain for safe and hygienic operation
-
Available in a range of media and removal ratings
* Stäubli is a trademark of Stäubli AG
材料成分
|
Filter Membrane |
Hydrophilic modified PVDF |
Support/Drainage |
聚丙烯 |
End Cap, Core and Cage |
聚丙烯 |
Capsule Bowl |
Polyetherimide |
Sealing Technology |
Thermal bonding without adhesives |
Housing Head |
Polyetherimide with TiO2 whitener¹ |
|
¹ TiO2 is an insoluble inorganic mineral filler that does not contribute to organic extractables
Operating Parameters²
|
Maximum Operating Temperature |
60 °C |
最大操作压力 |
6.5 bar (94 psi) at 40 °C
2.0 bar (29 psi) at 60 °C |
Maximum Differential Pressure (Forward Direction) |
5.3 bar (77 psi) at 40 °C
4.1 bar (60 psi) at 60 °C |
|
² In compatible fluids which do not soften, swell or adversely affect the filter or its materials of construction
Sterilization³
|
Autoclave or In-Situ steam |
3 x 60 minutes at 125 °C
10 x 60 minutes at 140 °C |
|
Typical Extractables in Water at 20 °C³
³ Tested on capsules without pre-flushing
Nominal Dimensions
|
Diameter Incl.Valves |
123 mm (4.8 in.) |
123 mm (4.8 in.) |
Overall Length |
84 mm (3.3 in.) |
157 mm (6.2 in.) |
|
Nominal Effective Filter Area (EFA)
|
C(LM)05 |
400 cm² (0.4 ft²) |
C(L)3 |
1500 cm² (1.6 ft²) |
|