- 254 mm (10 in.)
- 508 mm (20 in.)
- 762 mm (30 in.)
- 1016 mm (40 in.)
Their all-polypropylene construction makes them compatible with an extremely wide range of fluids.Cartridges are available in a P grade which is optimized for pharmaceutical applications.
注意事项:These filters are also available in Kleenpak Nova capsule format.
特色及优点
Pleated High-area
- Extraordinarily high dirt-holding capacity
- Long service life
- High flow-rates
- Excellent gel removal capability
Fixed Pore Structure
- No solids unloading under variations in flow or pressure differential
- Fibers will not migrate or become dislodged and contaminate process fluid
All-polypropylene Construction
- Extremely good chemical compatibility with a wide range of fluids
- Very low extractables
- No surfactants or binder resins are used during manufacture
- Continuous construction without side seam
- Media melt-sealed to solid components to ensure maximum integrity
Quality and Bio-Safety
Biological Tests
- Meets USP Biological Reactivity, In Vivo, for Class VI-121 °C plastics
Effluent Quality Tests*
- Meets Cleanliness per USP Particulates in Injectables
- Non-Fiber-Releasing
- Non-Pyrogenic per USP Bacterial Endotoxins (< 0.25 EU/mL)
- Meets Total Organic Carbon and Water Conductivity per USP Purified Water, pH per USP Sterile Purified Water
* Per lot sample soak or rinse-up flush aliquots.
材料成分
Filter Medium, Cage, Core, End Caps and Adapters | 聚丙烯 |
O 型圈 | Silicone or Ethylene Propylene (EPDM) as standard |
Maximum Operating Differential Pressures and Temperatures in Compatible Liquids1
Maximum Operating Temperature | 50 °C | 80 °C |
Maximum Differential Pressure | 5.0 bar (72 psi) | 3.4 bar (49 psi) |
Steam-sterilizing Temperature (in situ or Autoclave)
125 °C |
Cartridge Style
AB Code 3 P grade and AB Code 7 |
Maximum Recommended Cumulative Steam Life at 125 °C
10 hours |
Typical Flow Rates
注意事项:Differential pressures are for liquids with a viscosity of 1 cP.Differential pressures for liquids at other viscosities can be conservatively estimated by multiplying the indicated differential pressure by the viscosity in cP.For cartridges of 20 in. (508 mm), 30 in. (762 mm) and 40 in. (1016 mm) nominal length, divide the differential pressure by 2, 3 and 4 respectively.To obtain the total pressure drop of a complete filter assembly the housing pressure drop must be added.Please refer to the relevant housing literature

If the above table does not display clearly in your browser, you may download it here for easier viewing.