Provides rapid, efficient separation of biomolecules
- Omega™ membrane provides high recovery and typically results in > 90% recovery of target biomolecules
- New well design results in faster, more uniform filtration rates across the plate with reduced hold-up volume for maximum sample recovery
- Intrinsic plate and membrane properties prevent target molecules from binding to the plate
- 分子排阻
- PCR clean-up
- 核酸纯化
- 蛋白分离
材料成分
- Filter Media:Omega (modified polyethersulfone) membrane
- Plate Housing:Polyproylene
- Lid:Polystyrene
尺寸
- Length:12.8 cm (5.0 in.)
- Width:8.6 cm (3.4 in.)
- Height With Lid:1.8 cm (0.7 in.) (350 μL only)
- Height Without Lid:350 μL, 1.4 cm (0.6 in.);1 mL:3.3 cm (1.3 in.)
Well-Bottom Area
- 0.25 cm2
Recommended Working Volume
- 350 μL: < 300 μL
- 1 mL: < 900 μL
Recommended Operating Vacuum
- > 25.4 cm Hg (10 in.Hg)
Recommended Centrifugal Force
- 1,500 x g
Typical Vacuum Filtration Performance
膜 | Processing Time (min) | Hold-Up Volume (μL) |
10K Omega | 20 | 5 |
30K Omega | 8 | 6 |
100K Omega | 4 | 7 |
Typical Centrifugal Filtration Performance
膜 | Processing Time (min) | Hold-Up Volume (μL) |
3K Omega | 45 | 2 |
10K Omega | 8 | 2 |
30K Omega | 8 | 2 |
100K Omega | 5 | 2 |
Separation of Proteins with Omega Membrane Using Vacuum Filtration

SDS-PAGE analysis of reduced samples from 30K Omega membrane plate using vacuum separation method, 5 μL/lane.75 μL protein mix/well subjected to ~20 in.Hg vacuum for ~8 minutes.Each protein at 100 μg/mL in initial mix.ML = Marker Ladder; M1 = BSA; M2 = BSA + Cyt C; M3 = BSA, Carbonic Anydrase, and Cyto C; M4 = Carbonic Anhydrase.GelCode♦ Blue stain.
Related Literature
相关产品
- AcroPrep Advance Filter Plates for Multiplexing ensure assay reproducibility.
- AcroPrep Advance Filter Plates for Neonatal Screening for consitent performance and accurate results.
- AcroPrep Advance Filter Plates for Protein Purification have a versatile format for multiple purification strategies.
- AcroPrep Advance Filter Plates for Lysate Clearance provide efficient clarification of highly particulated samples.
- AcroPrep Advance Filter Plates for DNA Purification yield high quality DNA.
- AcroPrep Advance Filter Plates for Solvent Filtration provide compatibility with harsh organics.
- AcroPrep Advance Filter Plates for Aqueous Filtration for fast processing with efficient removal of particulates.
- AcroPrep 384-well Filter Plates for superior performance in high throughput sample preparation applications.
- Centrifugal Devices concentrate and purify samples of < 50 μL to 60 mL with efficient recovery and low non-specific binding.
- Chromatography Resins simplify protein purification and fractionation for biomarker discovery, proteomics research and drug development.
- Vacuum Manifold fits AcroWell and AcroPrep filter plates tightly for vacuum filtration.